VOLTA 2 is a high-power 2-channel portable ultrasonic instrument custom-designed for Electro Magnetic Acoustic Transducer (EMAT) applications. It features patented pulser technology capable of generating from 1-10 cycles at up to 1,000Vpp to satisfy the most energy-demanding EMAT applications in a compact and rugged package.

VOLTA 2 uses Innerspec Technologies Operating Platform (ITOP) with NDT-WEB application software. The instrument broadcasts a WiFi signal that permits remote control of the instrument from the removable phone/tablet (included) or from any connected wireless device using a standard web interface.

Applications & Software Options

APPLICATIONS - SOFTWARE Default Options
GENERAL APPLICATION:
THICKNESS MEASUREMENT
AND FLAW DETECTION (EMAT)
• CORROSION MAPPING
• ENCODED THICKNESS
• SURFACE WAVES
• ANGLED BEAM
MRUT
• TUBES & PIPES
• PLATES & TANKS
MRUT - SIZING
LRUT - LITE V2
LRUT - FOCUS
THIN WELDS
STRESS MEASUREMENT FOR RR WHEELS
NON-LINEAR UT
EXPERT

EMAT & DCUT Applications:

Default General Application includes:
Optional Software Applications:
  • MRUT for flaw detection with medium-range ultrasonic guided waves
  • MRUT SIZING. To provide remaining wall measurements on pipelines using MRUT axial scanning
  • LRUT-LITE for flaw detection with long-range ultrasonic guided waves using an axisymmetric magnetostrictive band in Pulse-Echo
  • LRUT-FOCUS for focusing LRUT with a patented receiver scanner
  • THIN WELDS for the inspection of welds under 6mm using Guided Waves.
  • STRESS MEASUREMENT FOR RAILROAD WHEELS
  • NON-LINEAR UT for damage characterization in early stages
  • EXPERT for researchers and advanced practitioners permits creating custom configurations with standard and advanced software tools and filters (FFT, IFFT, TCG, SAFT, Spectrograms, Dispersion Curves, Cancellation, Normalization, and Suppression).

Specifications

VOLTA 2 - Technical Specifications
Ultrasonic Channels 2
Bandwidth 20 kHz to 8 MHz – (All Normal Beam, Angled Beam, Guided Waves: LRUT, MRUT,)
Pulse Repetition Rate up to 1,000 Hz
RF Pulser 1-8 cycles, fixed and variable frequency tone-bursts
6 kW Power Output
1,000 Vpp @ 24 Amp pk-pk into 50 Ohms
1% Maximum Duty
Receiver LEMO Inputs:
1 kΩ Input Impedance16 dB to 100 dB Gain
<0.1 dB Gain Resolution

BNC Inputs:
1 kΩ Input Impedance-14 dB to 60 dB Gain
<0.1 dB Gain Resolution
Pulse / Receive Modes Pulse Echo (Uni- & Bi-Directional)
Pitch-Catch (Uni- & Bi-Directional)
Analog / Digital Converters 14-bit, 170Msps
Rectification Full-Wave
+/- Half Wave
RF Mode
Filtering FIR Digital Filters, Analog Bandpass filters
Evaluation Gates Auto-set gates (based on Wizard), User Adjustable
Encoder Interface 2x A/B Quadrature
PC Communication Wi-Fi 2x802.11ac/ax dual band
Bluetooth 5.0
USB 3.0, Ethernet
Software ITOP with NDT-WEB
Internal Storage Capacity 500 GB SSD
Internal Memory 8 GB RAM
Probe Connector Lemo, BNC, Thermocouple
Operating Temperature 32°F to 105°F (0°C to 40°C)
VOLTA USB Type-C power adapter input 100-240 VAC, 50-60 Hz
VOLTA USB Type-C power adapter output USB-PD 20V @ 5A, 100 W Max
VOLTA Rechargeable Battery Li-ion 14.4V @ 6.9Ah, 95.04 Wh, 4-8 hours, Hot-Swappable
Other I/O HDMI, Bluetooth, Thermocouple
Dimensions 16 W x 12 H x 6 D (in.)
406 W x 305 H x 152 D (mm)
Weight 20 lbs (9.1 kg)


Related Instruments

The following instruments are recommended for this application.
No items found.

SENSORS AND ACCESSORIES

Standard EMAT and DCUT Sensors and Accessories for the most common applications (normal beam, guided waves, angled beam)

VIEW
If you would like any more information on this system, please contact us, and one of our experts will be in touch.
CONTACT